Voordeelbundel
Bundle for Audiology Exams Compilation | Verified | Guaranteed Success
Bundle for Audiology Exams Compilation | Verified | Guaranteed Success
[Meer zien]Bundle for Audiology Exams Compilation | Verified | Guaranteed Success
[Meer zien]ENG stands for - Electronystagmography 
VNG stands for - Videonystagmography 
3 reasons to pick ENG over VNG - 1) patient has claustrophobia 2) patient has dark areas 
around eyes (permanent makeup/ injury) 3) patient is under age of 6 and VNG goggles don't fit 
on small head. 
Upward trace deflect...
Voorbeeld 3 van de 23 pagina's
In winkelwagenENG stands for - Electronystagmography 
VNG stands for - Videonystagmography 
3 reasons to pick ENG over VNG - 1) patient has claustrophobia 2) patient has dark areas 
around eyes (permanent makeup/ injury) 3) patient is under age of 6 and VNG goggles don't fit 
on small head. 
Upward trace deflect...
What is the ANSI standard for specification for audiometers? - ANSI S3.6-1996 (revised 
from 1989 standard). 
How are audiometers classified? - By Type 1, 2, 3, 4,,5 and HF and speech A, B, and C. The 
smaller the number, the more features the audiometer has. 
List the 5 types of audiometer classifi...
Voorbeeld 2 van de 10 pagina's
In winkelwagenWhat is the ANSI standard for specification for audiometers? - ANSI S3.6-1996 (revised 
from 1989 standard). 
How are audiometers classified? - By Type 1, 2, 3, 4,,5 and HF and speech A, B, and C. The 
smaller the number, the more features the audiometer has. 
List the 5 types of audiometer classifi...
The caloric test is designed to stimulate which of the following structures - The lateral 
semicircular canal 
To reduce adverse noise effects, the audiologist should make what adjustment - Enable 
expansion. Expansion reduces the gain of low-level ambient sounds. 
Individuals with normal hearing se...
Voorbeeld 4 van de 40 pagina's
In winkelwagenThe caloric test is designed to stimulate which of the following structures - The lateral 
semicircular canal 
To reduce adverse noise effects, the audiologist should make what adjustment - Enable 
expansion. Expansion reduces the gain of low-level ambient sounds. 
Individuals with normal hearing se...
what is the CPT code for comprehensive (air, bone, speech) - 92557 
What does sensitivity measure? 
Specificity? - Sensitivity measures the probability of actual positives 
specificity measures the probability of actual negatives. 
What is the formula for sensitivity? - Sensitivity= TP/(TP+FN) 
What...
Voorbeeld 4 van de 31 pagina's
In winkelwagenwhat is the CPT code for comprehensive (air, bone, speech) - 92557 
What does sensitivity measure? 
Specificity? - Sensitivity measures the probability of actual positives 
specificity measures the probability of actual negatives. 
What is the formula for sensitivity? - Sensitivity= TP/(TP+FN) 
What...
What does JCIH say about hearing loss? - Screen by 1 month, identify/followup by 3 
months, intervention by 6 months 
True or false: UNHS is now called EHDI - True, it's more about the process of intervention 
rather than just the screening 
What is IDEA? - Individuals with disabilities education a...
Voorbeeld 2 van de 9 pagina's
In winkelwagenWhat does JCIH say about hearing loss? - Screen by 1 month, identify/followup by 3 
months, intervention by 6 months 
True or false: UNHS is now called EHDI - True, it's more about the process of intervention 
rather than just the screening 
What is IDEA? - Individuals with disabilities education a...
Which of the following is true of the occlusion effect observed during pure tone audiometry? 
A.It results in artificially poorer thresholds at all frequencies. 
B.It can affect the measurement of air-conduction thresholds at low frequencies. 
C.It can affect the measurement of air-conduction thresh...
Voorbeeld 4 van de 72 pagina's
In winkelwagenWhich of the following is true of the occlusion effect observed during pure tone audiometry? 
A.It results in artificially poorer thresholds at all frequencies. 
B.It can affect the measurement of air-conduction thresholds at low frequencies. 
C.It can affect the measurement of air-conduction thresh...
Caloric test is designed to stimulate which of the following structures? - The lateral 
semicircular canal 
An individual who continues to react to new stimuli with responses that are carried over from 
previous tasks exhibits... - Perseveration 
What is a complete and accurate list of the signals r...
Voorbeeld 3 van de 23 pagina's
In winkelwagenCaloric test is designed to stimulate which of the following structures? - The lateral 
semicircular canal 
An individual who continues to react to new stimuli with responses that are carried over from 
previous tasks exhibits... - Perseveration 
What is a complete and accurate list of the signals r...
A patient comes to a clinic complaining of short, intense dizzy spells. An audiologist suspects 
that the patient may have benign paroxysmal positional vertigo (BPPV). Which of the following 
tests is most appropriate to use to confirm the diagnosis? - Dix-Hallpike test 
0 dB0 decibels HL is best de...
Voorbeeld 4 van de 34 pagina's
In winkelwagenA patient comes to a clinic complaining of short, intense dizzy spells. An audiologist suspects 
that the patient may have benign paroxysmal positional vertigo (BPPV). Which of the following 
tests is most appropriate to use to confirm the diagnosis? - Dix-Hallpike test 
0 dB0 decibels HL is best de...
For which of the following instruments do national standards or uniform performance standards 
for calibration exist? 
a. Pure tone audiometers 
b. OAEs 
c. ABR 
d. all have calibration standards - Pure tone audiometers 
Only pure tone audiometers have established (ANSI) standards for calibration 
W...
Voorbeeld 4 van de 37 pagina's
In winkelwagenFor which of the following instruments do national standards or uniform performance standards 
for calibration exist? 
a. Pure tone audiometers 
b. OAEs 
c. ABR 
d. all have calibration standards - Pure tone audiometers 
Only pure tone audiometers have established (ANSI) standards for calibration 
W...
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Preach. Stuvia faciliteert de betaling aan de verkoper.
Nee, je koopt alleen deze samenvatting voor $40.49. Je zit daarna nergens aan vast.
4,6 sterren op Google & Trustpilot (+1000 reviews)
Afgelopen 30 dagen zijn er 85483 samenvattingen verkocht
Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen