When placing a LOTO on a system, how many locks should be applied? - As many locks as their 
are personnel working on the system. 
A ladder must be able to support ____ times the weight of the expected load - 3.3 
It is acceptable to enter into a confined space without an attendant, but only if all ...
Vista previa 2 fuera de 14 páginas
Añadir al carritoWhen placing a LOTO on a system, how many locks should be applied? - As many locks as their 
are personnel working on the system. 
A ladder must be able to support ____ times the weight of the expected load - 3.3 
It is acceptable to enter into a confined space without an attendant, but only if all ...
Standby power - 24 hours 1 
Alarm Power - 5 minutes 
MNS Power - 15 minutes 
household alarm power -4 minutes 1 
battery safety margin - 20 % 
switch to secondary power - 10 seconds 2 
alarm turn on time - 10 seconds 1 
supervisory signal time - 90 seconds 
trouble signal time - 200 seconds 
operati...
Vista previa 2 fuera de 7 páginas
Añadir al carritoStandby power - 24 hours 1 
Alarm Power - 5 minutes 
MNS Power - 15 minutes 
household alarm power -4 minutes 1 
battery safety margin - 20 % 
switch to secondary power - 10 seconds 2 
alarm turn on time - 10 seconds 1 
supervisory signal time - 90 seconds 
trouble signal time - 200 seconds 
operati...
Who is responsible for the inspection, testing, maintenance and impairment of a water based fire 
protection system? - The Property owner or designated representative 
Who's responsibility is it to provide accessibility to components of a water based fire protection system? 
- The property owner or...
Vista previa 2 fuera de 10 páginas
Añadir al carritoWho is responsible for the inspection, testing, maintenance and impairment of a water based fire 
protection system? - The Property owner or designated representative 
Who's responsibility is it to provide accessibility to components of a water based fire protection system? 
- The property owner or...
if a combination audible/visible appliances are installed, the location of the installed appliance shall be 
determined by the requirements of - the visible appliance 
what is the maximum number of 12-gaugeTHHN conductors that can be installed in 1-inch EMT - 
26 
Do you resistors are connected in p...
Vista previa 1 fuera de 3 páginas
Añadir al carritoif a combination audible/visible appliances are installed, the location of the installed appliance shall be 
determined by the requirements of - the visible appliance 
what is the maximum number of 12-gaugeTHHN conductors that can be installed in 1-inch EMT - 
26 
Do you resistors are connected in p...
Fire Alarm Code? - NFPA 72 
National Electric Code? -NFPA 70 
AHJ? - Authority Having Jurisdiction 
Disconnecting means for fire alarm power shall be what color? - Red 
If a combination audible visible appliance is installed, the location of the installed appliance shall be 
determined by the requir...
Vista previa 2 fuera de 10 páginas
Añadir al carritoFire Alarm Code? - NFPA 72 
National Electric Code? -NFPA 70 
AHJ? - Authority Having Jurisdiction 
Disconnecting means for fire alarm power shall be what color? - Red 
If a combination audible visible appliance is installed, the location of the installed appliance shall be 
determined by the requir...
What is a purpose of a control valve - Control Flow to water based fire protection system 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system 
side of the dry pipe valve? - the same pressure 
What type of test shall be provided when a valve is returned ...
Vista previa 2 fuera de 5 páginas
Añadir al carritoWhat is a purpose of a control valve - Control Flow to water based fire protection system 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system 
side of the dry pipe valve? - the same pressure 
What type of test shall be provided when a valve is returned ...
Consider a room which is 40' square. How many 15cd wall mounted strobes are required to adequately 
cover this space? - 4 
What is the testing frequency of a strobe? - Annually 
In a corridor application, visible appliances shall be rated not less than ________ cd? - 15 
Consider a household fire a...
Vista previa 1 fuera de 4 páginas
Añadir al carritoConsider a room which is 40' square. How many 15cd wall mounted strobes are required to adequately 
cover this space? - 4 
What is the testing frequency of a strobe? - Annually 
In a corridor application, visible appliances shall be rated not less than ________ cd? - 15 
Consider a household fire a...
When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval 
for testing? - 18 months 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum 
mounting height from the floor? - 66 inches 
Elevator lobby smoke d...
Vista previa 2 fuera de 10 páginas
Añadir al carritoWhen a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval 
for testing? - 18 months 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum 
mounting height from the floor? - 66 inches 
Elevator lobby smoke d...
Secondary power for remote supervising station systems shall be capable of normal operation for ___ 
hours and then operate the system in alarm for ___ minutes? - 24 / 5 
A fire alarm system which serves contiguous or noncontiguous properties under one ownership is 
considered? - Proprietary system ...
Vista previa 2 fuera de 6 páginas
Añadir al carritoSecondary power for remote supervising station systems shall be capable of normal operation for ___ 
hours and then operate the system in alarm for ___ minutes? - 24 / 5 
A fire alarm system which serves contiguous or noncontiguous properties under one ownership is 
considered? - Proprietary system ...
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water 
level _____________from the required level - rises or falls over 3 inches (NFPA 72, Table 14.4.3.2 
17 (j) (4) 
If combination audible/visible appliances are installed the location of the inst...
Vista previa 1 fuera de 2 páginas
Añadir al carritoWhen testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water 
level _____________from the required level - rises or falls over 3 inches (NFPA 72, Table 14.4.3.2 
17 (j) (4) 
If combination audible/visible appliances are installed the location of the inst...
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water 
level _____________from the required level 
(NFPA 72, Table 14.4.3.2 17 (j) (4) - rises or falls over 3 inches 
If combination audible/visible appliances are installed the location of the inst...
Vista previa 3 fuera de 17 páginas
Añadir al carritoWhen testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water 
level _____________from the required level 
(NFPA 72, Table 14.4.3.2 17 (j) (4) - rises or falls over 3 inches 
If combination audible/visible appliances are installed the location of the inst...
When using a pulse load tester on a sealed lead acid battery, the minimum acceptable capacity is... - 
80% 
When a software change is made to a fire alarm system, what percentage of the initiating devices not 
affected by the change must be tested - 10% 
When testing elevator recall, the elevator sh...
Vista previa 2 fuera de 7 páginas
Añadir al carritoWhen using a pulse load tester on a sealed lead acid battery, the minimum acceptable capacity is... - 
80% 
When a software change is made to a fire alarm system, what percentage of the initiating devices not 
affected by the change must be tested - 10% 
When testing elevator recall, the elevator sh...
A green color code green indication on a heat detector indicates what operating temperature 
classification ? - Very Extra High 
A ground electrode shall be a minimum of _____feet in length? - 8 feet 
A multi criteria device shall be ____ for the primary function of the device - listed 
A non power ...
Vista previa 2 fuera de 8 páginas
Añadir al carritoA green color code green indication on a heat detector indicates what operating temperature 
classification ? - Very Extra High 
A ground electrode shall be a minimum of _____feet in length? - 8 feet 
A multi criteria device shall be ____ for the primary function of the device - listed 
A non power ...
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.
No, you only buy this summary for $19.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
45,681 summaries were sold in the last 30 days
Founded in 2010, the go-to place to buy summaries for 14 years now