4th tssa Samenvattingen, Aantekeningen en Examens

Op zoek naar een samenvatting over 4th tssa? Op deze pagina vind je 36 samenvattingen over 4th tssa.

Alle 36 resultaten

Sorteer op

4th TSSA Part B Test (II) Questions with complete Solutions!!
  • 4th TSSA Part B Test (II) Questions with complete Solutions!!

  • Tentamen (uitwerkingen) • 10 pagina's • 2024
  • 4th TSSA Part B Test (II) Questions with complete Solutions!!
    (0)
  • $13.99
  • + meer info
4th TSSA Part B Test (I) Questions With 100% Correct Answers!!
  • 4th TSSA Part B Test (I) Questions With 100% Correct Answers!!

  • Tentamen (uitwerkingen) • 10 pagina's • 2024
  • 4th TSSA Part B Test (I) Questions With 100% Correct Answers!!
    (0)
  • $13.99
  • + meer info
4th TSSA Part A Unit 1 Exam Questions and Answers
  • 4th TSSA Part A Unit 1 Exam Questions and Answers

  • Tentamen (uitwerkingen) • 9 pagina's • 2023
  • 4th TSSA Part A Unit 1 Exam Questions and Answers (4-009-2.3) The ability of a body to do work due to its motion is called ____________ energy. - Answer-Kinetic (4-009-1.7) The change of position (in meters) per unit time is: - Answer-Velocity (4-015-1.5) The force of friction is: - Answer-Not affected by the area of the two surfaces in contact. (4-012-1.11) With reference to scalars and vectors, a space diagram: - Answer-Illustrates a system of vectors. (4-016-3.3) A 1.5m long r...
    (0)
  • $14.59
  • + meer info
4th TSSA Part B Test (I) 150 Questions With 100% Correct Answers.
  • 4th TSSA Part B Test (I) 150 Questions With 100% Correct Answers.

  • Tentamen (uitwerkingen) • 14 pagina's • 2023
  • Ook in voordeelbundel
  • When a combustion air opening is equipped with dampers, the dampers must be - interlocked with the burner, and fully open before starting the boiler. R4B A substance that absorbs humidity inside a boiler during dry layup is: - Activated alumina (4-142-1.3) The high oil temperature shutdown device of an oil-fired heater senses the: - Oil temperature at the furnace outlet R4B A boiler furnace pre-purge: - must last a specific amount of time. R4B In a building plumbing system, the potable wa...
    (0)
  • $7.99
  • + meer info
4th TSSA Part B Unit 4 Exam Questions and Answers
  • 4th TSSA Part B Unit 4 Exam Questions and Answers

  • Tentamen (uitwerkingen) • 7 pagina's • 2023
  • 4th TSSA Part B Unit 4 Exam Questions and Answers Larger capacity, high pressure fuel trains are - Answer-more complex The main burner test firing valve should be opened - Answer-before starting the main burner What is the recommended boiler water pH for wet layup? - Answer-10 R4B Failure to _____ the furnace thoroughly before light-up can cause a furnace explosion. - Answer-purge R4B When cooling down a steam boiler that has been taken out of service, a vent valve on a steam drum ...
    (0)
  • $13.49
  • + meer info
4th TSSA Part A (I) with Complete Solutions 2024
  • 4th TSSA Part A (I) with Complete Solutions 2024

  • Tentamen (uitwerkingen) • 10 pagina's • 2024
  • 4th TSSA Part A (I) with Complete Solutions 2024
    (0)
  • $10.49
  • + meer info
4th TSSA Part B - Unit 9 Test 2023
  • 4th TSSA Part B - Unit 9 Test 2023

  • Tentamen (uitwerkingen) • 10 pagina's • 2023
  • 4th TSSA Part B - Unit 9 Test 2023...
    (0)
  • $10.49
  • + meer info
4th TSSA Part B Test (II) | 150 Questions with 100% Correct Answers | Verified | Latest Update 2024
  • 4th TSSA Part B Test (II) | 150 Questions with 100% Correct Answers | Verified | Latest Update 2024

  • Tentamen (uitwerkingen) • 14 pagina's • 2023
  • Ook in voordeelbundel
  • (4-075-int.1) Compressed air tools tend to be: - More expensive than electrical tools R4B Temperature relief devices limit the temperature in domestic hot water systems to no more than: - 99°C (4-143-2.14) What is the primary use of the ground wood pulp, produced by the mechanical process? - Newsprint R4B The cheapest and most commonly used grease is: - Lime base R4B In a circulatingdomestichot water system, automatic air vents - Remove air that is released when water is heated R4B Natu...
    (0)
  • $15.49
  • + meer info
4th TSSA Part B Test (I) 150 Questions with 100% Correct Answers | Verified | Latest Update 2024
  • 4th TSSA Part B Test (I) 150 Questions with 100% Correct Answers | Verified | Latest Update 2024

  • Tentamen (uitwerkingen) • 14 pagina's • 2023
  • Ook in voordeelbundel
  • When a combustion air opening is equipped with dampers, the dampers must be - interlocked with the burner, and fully open before starting the boiler. R4B A substance that absorbs humidity inside a boiler during dry layup is: - Activated alumina (4-142-1.3) The high oil temperature shutdown device of an oil-fired heater senses the: - Oil temperature at the furnace outlet R4B A boiler furnace pre-purge: - must last a specific amount of time. R4B In a building plumbing system, the potable wa...
    (0)
  • $15.49
  • + meer info
4th TSSA Part B Unit 4 Exam Questions and Answers
  • 4th TSSA Part B Unit 4 Exam Questions and Answers

  • Tentamen (uitwerkingen) • 7 pagina's • 2023
  • 4th TSSA Part B Unit 4 Exam Questions and Answers Larger capacity, high pressure fuel trains are - Answer-more complex The main burner test firing valve should be opened - Answer-before starting the main burner What is the recommended boiler water pH for wet layup? - Answer-10 R4B Failure to _____ the furnace thoroughly before light-up can cause a furnace explosion. - Answer-purge R4B When cooling down a steam boiler that has been taken out of service, a vent valve on a steam drum sh...
    (0)
  • $9.99
  • + meer info