Elevator mechanic exam Guides d'étude, Notes de cours & Résumés

Vous recherchez les meilleurs guides d'étude, notes d'étude et résumés sur Elevator mechanic exam ? Sur cette page, vous trouverez 413 documents pour vous aider à réviser pour Elevator mechanic exam.

All 413 résultats

Trier par

Elevator Mechanic Exam Review Questions and answers 2023 With Complete Solution Graded and Already Passed. Très apprécié
  • Elevator Mechanic Exam Review Questions and answers 2023 With Complete Solution Graded and Already Passed.

  • Examen • 11 pages • 2023 Très apprécié
  • A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" sheave. What sheave is required? - CORRECT ANS Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What should you do? - CORRECT ANS Replace it with a larger MOV On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the issue? - CORRECT ANS Suicide Circ...
    (0)
  • $11.49
  • 2x vendu
  • + en savoir plus
Elevator Mechanic Exam Review 2023: Verified Solutions (A+ Guaranteed)
  • Elevator Mechanic Exam Review 2023: Verified Solutions (A+ Guaranteed)

  • Examen • 30 pages • 2023
  • 1. A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" sheave. What sheave is required?: Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave 2. A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What should you do?: Replace it with a larger MOV 3. On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the issue?: Suicide Circuit 4. You have an old DC ...
    (0)
  • $8.49
  • 7x vendu
  • + en savoir plus
Elevator Mechanic Exam 2023 Questions and Answers with Complete Solutions
  • Elevator Mechanic Exam 2023 Questions and Answers with Complete Solutions

  • Examen • 20 pages • 2023
  • Elevator Mechanic Exam 2023 Questions and Answers with Complete Solutions
    (0)
  • $12.49
  • 2x vendu
  • + en savoir plus
Elevator Mechanic Exam 2023 Questions With Complete Solutions
  • Elevator Mechanic Exam 2023 Questions With Complete Solutions

  • Examen • 26 pages • 2023
  • Know the formula for RPM correct answer: RPM = 60 ∙ ƒ ÷ P÷2 = Step 1. 60 x Frequency (Hz.) = Step 2. Poles ÷ 2 = Take answer 1 and ÷ by answer 2 = You are using a Temp Run Box and you get shocked! Why! 520 Pg. 4 correct answer: Bad Ground Scaffolding, You have 32' of rise, you are using 3x5 scaffolding. Where will the tie off points be ? 140 PG. 287-288 correct answer: Scaffolding should be tied to the structure using #9 wire or tie-in devices. The first vertical tie ...
    (0)
  • $10.49
  • 1x vendu
  • + en savoir plus
Elevator Mechanic Exam Review 2022 216 Questions with 100% Correct Answers – COMPLETE SOLUTION
  • Elevator Mechanic Exam Review 2022 216 Questions with 100% Correct Answers – COMPLETE SOLUTION

  • Examen • 22 pages • 2022
  • A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" sheave. What sheave is required? - Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What should you do? - Replace it with a larger MOV On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the issue? - Suicide Circuit You have an old DC motor ...
    (1)
  • $10.49
  • 16x vendu
  • + en savoir plus
Elevator Mechanic Exam Review exam 2022/023
  • Elevator Mechanic Exam Review exam 2022/023

  • Examen • 17 pages • 2022
  • A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" sheave. What sheave is required? - Answer- Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What should you do? - Answer- Replace it with a larger MOV On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the issue? - Answer- Suicide Circuit ...
    (0)
  • $12.49
  • 1x vendu
  • + en savoir plus
NEIEP 200 Final Exam Version 2 (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A
  • NEIEP 200 Final Exam Version 2 (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A

  • Examen • 22 pages • 2023
  • NEIEP 200 Final Exam Version 2 (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A Q: a mechanic attaches a chainfall to a hoisting beam with a beam clamp. what happens to the capacity of the hoisting beam? Answer: it is reduced to 50% of original capacity Q: you are rigging elevator equipment with a sling angle of 60 degrees. you are using a shouldered eye bolt with a tapped 1/2" diameter hole. once the shoulder is seated, what is the minimum threa...
    (0)
  • $10.99
  • 1x vendu
  • + en savoir plus
Elevator Mechanic Exam Review Elevator Mechanic  Study Questions with COMPLETE SOLUTIONS  (LATEST)
  • Elevator Mechanic Exam Review Elevator Mechanic Study Questions with COMPLETE SOLUTIONS (LATEST)

  • Examen • 126 pages • 2024
  • Elevator Mechanic Exam Review Elevator Mechanic Study Questions with COMPLETE SOLUTIONS (LATEST) If rigging gear is roped 3:1 and a BEAM CLAMP is used to lift a 6,000lb load. What is the beam capacity? - CORRECT ANSWER 18,000lbs. Beam capacity is cut in half with use of clamp, when rigging all blocks, rope, and clamps will be Equal to the lowest load rating What are the consequences of misaligned joints on a Rack and Pinion? - CORRECT ANSWER Broken Gear teeth. CWT derailment. Excess...
    (0)
  • $12.49
  • + en savoir plus